How to do if the laser marking machine is not clear enough

The laser intensity decreases and the marking is not clear enough. The following solutions can be adopted:

1. Whether the laser cavity changes; fine-tune the cavity lens. Adjust the output spot to the proper focus.

2. The acousto-optic crystal is shifted or the acousto-optic power output is low. Adjust the position of the acousto-optic crystal or increase the acousto-optic power workflow.

3. The laser entering the galvanometer is off-center: adjust the laser;

4. If the current is adjusted to about 20A, the sensitivity is still not enough: contact the after-sales

The following reasons may also cause the laser marking machine to be unclear:

1. The lens is too dirty, soak a little alcohol with cotton, then gently wipe the lens surface;

2. The marking speed is too fast, which can reduce the marking speed, thereby increasing the filling density;

3. The laser power current is not on or the power flow is too small. Turn on the power current or increase the power of the power current;

4. The laser has a useful life, which may be due to its service life, and the laser needs to be replaced.

If you still don't understand, please contact us.

CKlaser is a national high-tech enterprise integrating laser equipment research and development, production, sales and service. 

Since its establishment, CK Laser has always attached importance to R & D innovation and adhered to the self-developed product line. It has formed a top team of more than 60 senior software engineers, mechanical engineers, electrical engineers and industrial designers who have been in the laser field for more than ten years. Technical R & D team.